In the trunking vs conduit choice, trunking is a channel with a lid fixed on the surface of a wall, quick to fit and easy to open later; conduit is a round pipe chased into brick or cast in a concrete slab and plastered over, so the wiring disappears. Trunking suits finished, lived in or face brick buildings. Conduit suits new builds before the plaster, and anywhere the wall must look untouched. Plenty of jobs use both. Here is how to decide, room by room.
Side by side
| Trunking | Conduit | |
|---|---|---|
| Where it goes | On the wall, ceiling or skirting | In the wall or slab, or saddled on the surface |
| Mess | Drill holes only | Chasing, dust, plaster and paint |
| Speed | Fast on finished walls | Fast only before plastering |
| Adding a circuit | Unclip the lid, lay it in | Pull through, if there is space and a draw wire |
| Looks | Visible, can be painted | Hidden |
| Lengths | Usually 3 m | Usually 4 m, 20 and 25 mm in houses |
When trunking is the better call
Face brick cannot be chased without leaving a scar that no patch hides, so in a face brick lounge or a church hall the answer is nearly always trunking. Off shutter concrete in a modern townhouse is the same. Offices that rearrange desks every two years, rented flats where the landlord will not allow chasing, and occupied schools where dust in a classroom is a problem all lean the same way. Trunking also gives you spare space: size it for the space factor of about 45 percent and you can add a data cable later without breaking anything. See PVC trunking for the common profiles.
When conduit is the better call
On a new build the brickwork is open and the plasterer has not arrived, so chasing costs little and the walls finish clean. Conduit can also be laid in the slab before the pour, with the electrician fixing bends and boxes to the reinforcing. Bedrooms and lounges where a client does not want any visible run suit it. Leave a draw wire in every pipe and keep to about 40 percent fill; the conduit fill calculator gives the diameter. More on sizes and fittings on the conduit pipe page.
Mixing them: the trunking to conduit connection
A common hybrid: trunking runs along the wall at plug height and short conduit drops leave it to reach a switch or an isolator. The trunking to conduit connection is a hole cut in the base with a hole saw, a conduit adaptor or box connector locked in, and a bush so no cable rubs on a sharp edge. Use adaptors made for the trunking range. With steel on either side, the electrician bonds across the joint. The trunking accessories page shows the adaptor types.
What to put in your request
- List the rooms and what each wall is made of
- Say if it is a new build or occupied building
- Count the plugs, switches and data points
- Ask for trunking and conduit priced apart
- Ask whether plaster and paint are included
Trunking vs Conduit: who asks for them and why
- Homeowners, landlords and DIY: deciding between chasing a plastered bedroom wall or a painted surface run
- Electricians and electrical contractors: pricing both methods for a client who has not made up their mind
- Offices, co-working spaces and IT teams: trunking for floors that change, conduit only where walls are new partitions
- Shops, restaurants, salons and malls: surface runs in a leased shop where the landlord forbids chasing walls
- Factories, warehouses, mines and workshops: saddled steel conduit or steel trunking along exposed block walls in a workshop
- Builders, developers and shopfitters: conduit cast in the slab and chased before plaster on a new block of units
- Server rooms, data, CCTV and solar installers: conduit drops to each camera off a trunking run along the eaves
- Schools, clinics, churches and municipalities: trunking in an occupied school where chasing dust would close classrooms